Search results for "PIN diode"
showing 8 items of 8 documents
SphinX soft X-ray spectrophotometer: Science objectives, design and performance
2011
The goals and construction details of a new design Polish-led X-ray spectrophotometer are described. The instrument is aimed to observe emission from entire solar corona and is placed as a separate block within the Russian TESIS X- and EUV complex aboard the CORONAS-PHOTON solar orbiting observatory. SphinX uses silicon PIN diode detectors for high time resolution measurements of the solar spectra in the range 0.8–15 keV. Its spectral resolution allows for discerning more than hundred separate energy bands in this range. The instrument dynamic range extends two orders of magnitude below and above these representative for GOES. The relative and absolute accuracy of spectral measurements is e…
Design, upgrade and characterization of the silicon photomultiplier front-end for the AMIGA detector at the Pierre Auger Observatory
2021
The successful installation, commissioning, and operation of the Pierre Auger Observatory would not have been possible without the strong commitment and effort from the technical and administrative staff in Malargue. We are very grateful to the following agencies and organizations for financial support: Argentina -Comision Nacional de Energia Atomica; Agencia Nacional de Promocion Cientifica y Tecnologica (ANPCyT); Consejo Nacional de Investigaciones Cientificas y Tecnicas (CONICET); Gobierno de la Provincia de Mendoza; Municipalidad de Malargue; NDM Holdings and Valle Las Lenas; in gratitude for their continuing cooperation over land access; Australia -the Australian Research Council; Braz…
The FRAM robotic telescope for atmospheric monitoring at the Pierre Auger Observatory
2021
FRAM (F/Photometric Robotic Atmospheric Monitor) is a robotic telescope operated at the Pierre Auger Observatory in Argentina for the purposes of atmospheric monitoring using stellar photometry. As a passive system which does not produce any light that could interfere with the observations of the fluorescence telescopes of the observatory, it complements the active monitoring systems that use lasers. We discuss the applications of stellar photometry for atmospheric monitoring at optical observatories in general and the particular modes of operation employed by the Auger FRAM. We describe in detail the technical aspects of FRAM, the hardware and software requirements for a successful operati…
Calibration of the underground muon detector of the Pierre Auger Observatory
2021
To obtain direct measurements of the muon content of extensive air showers with energy above $10^{16.5}$ eV, the Pierre Auger Observatory is currently being equipped with an underground muon detector (UMD), consisting of 219 10 $\mathrm{m^2}$-modules, each segmented into 64 scintillators coupled to silicon photomultipliers (SiPMs). Direct access to the shower muon content allows for the study of both of the composition of primary cosmic rays and of high-energy hadronic interactions in the forward direction. As the muon density can vary between tens of muons per m$^2$ close to the intersection of the shower axis with the ground to much less than one per m$^2$ when far away, the necessary bro…
Measurements of the stopping forces for heavy ions in Ge, Ag and Au using novel ‘polka-dot’ detectors
2006
Measurements of the stopping forces for C-14, N-14 and O-16 ions in Ge and Au, for N-14 and F-19 ions in Ag, as well as for F-19 ions in Au have been made, respectively. A novel technique, reported recently, using PIN diodes coated directly with the stopping medium in a polka dot pattern was used. This provided a set of precise, self-consistent measurements on the same stopping medium. Results show small but significant deviations from SRIM stopping predictions and are also compared to a recently-developed empirical stopping force predictor.
Nano-imaging of single cells using STIM
2007
Scanning transmission ion microscopy (STIM) is a technique which utilizes the energy loss of high energy (MeV) ions passing through a sample to provide structural images. In this paper, we have successfully demonstrated STIM imaging of single cells at the nano-level using the high resolution capability of the proton beam writing facility at the Centre for Ion Beam Applications, National University of Singapore. MCF-7 breast cancer cells (American Type Culture Collection [ATCC]) were seeded on to silicon nitride windows, backed by a Hamamatsu pin diode acting as a particle detector. A reasonable contrast was obtained using 1 MeV protons and excellent contrast obtained using 1 MeV alpha parti…
Adaption of a PIN-diode detector as an online neutron monitor for the thermal column of the TRIGA research reactor.
2017
A BNCT online neutron monitoring system was tested in a TRIGA reactor, using a silicon PIN-diode with a conversion foil. The setup was tested with different reactor powers at the hot and cold ends of the irradiation channel, using activation foils to compare with measured fluxes. The results demonstrate good reproducibility and show a linear correlation between signal of the PIN-diode and neutron flux at all positions, demonstrating this approach to be suitable for online monitoring of the neutron flux.
Simulation studies of electronic transport in a-Si:H thin film solar cells
2009
The thin film solar cells in Hydrogenated Amorphous Silicon (a-Si:H) are attractive for cheaper production and used in ultra low cost, high volume applications but have a relatively lower electronic performance. These limitations are mainly due to properties of the a-Si:H and relies on the production technique. In this study we investigate the physical mechanisms which are on the basis of the electronic transport and their relation with the technological processes. The transport-simulation computer program ATLAS (Silvaco) has been used to examine the role of the mid gap defect density in determining the performance of a-Si:H p-i-n homojunction solar cell.